Why ACB Getting Heating Issue? – 4 Core Reasons

Why ACB Getting Heating Issue – Complete Guide with Causes, Effects, and Solutions

“Discover the common causes of ACB heating issues, their effects, troubleshooting tips, and proven solutions. Learn why Air Circuit Breakers get hot and how to prevent failures with proper maintenance.”

Air Circuit Breakers (ACB) are widely used in industrial, commercial, and utility power distribution systems. They play a critical role in protecting equipment and electrical networks from overloads, short circuits, and other abnormal conditions. However, one of the most common concerns with ACBs is heating issues.

If you’ve ever wondered “Why ACB getting heating issue?”, this article covers everything you need to know: the causes, effects, troubleshooting methods, and long-term preventive measures.

Introduction to ACB Heating Issues

An Air Circuit Breaker operates by interrupting current flow during fault conditions and ensuring the system stays safe. It is designed to carry rated current without overheating. But in real-world applications, users often notice that the breaker body, terminals, or contacts become unusually warm or even hot.

This heating is not just an inconvenience—it may indicate serious underlying issues such as poor connections, overload, improper maintenance, or design limitations. If ignored, it can lead to breakdowns, equipment damage, fire hazards, or even complete power system failures.

That’s why it is essential to understand why ACBs get heating issues and how to resolve them.

Basics of Air Circuit Breakers (ACB)

Before diving deep into the heating issue, let’s first recap what ACBs are and how they work.

1. What is an ACB?

An Air Circuit Breaker is a type of circuit breaker where air is used as the arc extinguishing medium. They are typically used for low-voltage applications (up to 1000V AC) in power distribution systems.

2. Functions of an ACB:

  • Protects electrical circuits from overload and short circuit conditions.
  • Provides manual or automatic switching of loads.
  • Ensures continuity of service in case of faults.
  • Protects equipment like transformers, generators, and motors.

3. Major Parts of ACB:

  • Contacts (fixed and moving)
  • Arc chute
  • Operating mechanism
  • Trip unit
  • Terminals and busbar connections

Each of these components can be linked to heating issues if not properly maintained.

Why ACB Getting Heating Issue? – The Core Reasons

Now, let’s explore in detail the reasons why ACBs develop heating problems. These can be broadly categorized into electrical, mechanical, environmental, and operational causes.

1. Electrical Causes

(a) Loose Connections

One of the most common reasons for heating in ACBs is loose terminal connections. When current flows through a loose joint, the resistance increases, leading to localized heating. This can further worsen the connection, creating a vicious cycle.

(b) Overloading

If the connected load exceeds the breaker’s rated capacity, it causes continuous high current flow. Overloading results in:

  • High I²R losses (current squared times resistance).
  • Excessive heating of conductors and contacts.

(c) Phase Imbalance

In a three-phase system, if loads are not balanced, one or two phases may carry more current than others. This imbalance causes uneven heating in ACB poles.

(d) Short Circuits or Faulty Equipment

Even if the fault is temporary, repeated short circuits can stress the breaker contacts and generate significant heat.

(e) Harmonics in Load

Non-linear loads (like VFDs, UPS systems, LED lighting) generate harmonics. Harmonic currents increase heating in conductors and breakers.

(f) Poor Contact Resistance

Worn-out or oxidized contacts increase resistance, which directly leads to excessive heating at the contact points.

2. Mechanical Causes

(a) Wear and Tear of Contacts

After repeated operations, contacts lose their smoothness or alignment, increasing resistance.

(b) Improper Contact Pressure

If the contact spring or mechanism does not provide enough force, arcing and overheating occur.

(c) Deformation of Terminals

Due to previous overheating or mechanical stress, the shape of terminals may deform, reducing surface contact.

3. Environmental Causes

(a) High Ambient Temperature

When the surrounding temperature is higher than the breaker’s design limit, internal heating issues worsen.

(b) Dust and Contamination

Dust, oil, and moisture deposit on the breaker surface and contacts, restricting heat dissipation.

(c) Corrosion

Humidity and pollution cause corrosion of metallic parts, leading to increased resistance and heating.

4. Operational Causes

(a) Frequent Tripping

Repeated tripping due to system faults generates arc heat, damaging the breaker.

(b) Improper Sizing of ACB

Using an undersized ACB for a large load will definitely cause heating issues.

(c) Poor Maintenance Practices

Neglecting routine inspection, lubrication, and cleaning leads to unnoticed defects that cause overheating.

Effects of Heating in ACB

Heating in an ACB is not just a minor inconvenience. It can have serious consequences on the performance, safety, and life of the breaker.

  1. Reduced Life of Contacts – Excess heat causes faster erosion of contacts.
  2. Insulation Damage – Overheating can break down insulation, leading to short circuits.
  3. Nuisance Tripping – The breaker may trip frequently, disrupting power supply.
  4. Energy Loss – Excess I²R loss increases operating costs.
  5. Fire Hazard – In extreme cases, continuous overheating may ignite insulation or nearby material.
  6. System Downtime – Heating-related failure can shut down entire power systems, leading to costly downtime.

Troubleshooting ACB Heating Issues

If you are facing heating issues with your ACB, here’s a step-by-step troubleshooting guide:

1. Visual Inspection

  • Check for discoloration of terminals (sign of overheating).
  • Look for melted insulation or burn marks.
  • Inspect for dust, dirt, or corrosion.

2. Thermal Scanning

Interestingautomation.com

Use an infrared thermal scanner to identify hot spots in the breaker.

3. Tightness Check

Ensure all connections are properly tightened as per manufacturer torque specifications.

4. Load Analysis

  • Measure current on each phase.
  • Identify overload or imbalance conditions.

5. Contact Resistance Test

Perform millivolt drop or contact resistance testing to detect worn-out contacts.

6. Insulation Resistance Test

Check insulation health using a megger.

7. Harmonic Analysis

Measure total harmonic distortion (THD) in the system to identify nonlinear loads.

Solutions for ACB Heating Problems

Once you identify the cause, apply corrective measures:

Electrical Solutions

  • Tighten or replace loose connections.
  • Replace worn-out or oxidized contacts.
  • Balance three-phase loads.
  • Upgrade ACB rating if current exceeds design limit.
  • Install harmonic filters if harmonic currents are high.

Mechanical Solutions

  • Replace damaged springs or contact mechanisms.
  • Realign or replace deformed terminals.
  • Apply proper lubrication to moving parts.

Environmental Solutions

  • Improve ventilation in the panel room.
  • Use air conditioning or forced cooling if ambient temperature is high.
  • Regular cleaning to remove dust and moisture.

Operational Solutions

  • Avoid frequent manual tripping unless required.
  • Perform scheduled preventive maintenance.
  • Train staff on proper breaker operation.

Preventive Maintenance Practices

To avoid ACB heating issues in the long term, follow these preventive maintenance measures:

  1. Regular Inspection Schedule – Inspect ACB at least once every 3–6 months.
  2. Torque Testing – Always ensure terminal bolts are tightened as per standards.
  3. Contact Maintenance – Clean and dress contacts periodically. Replace when wear limit is reached.
  4. Thermal Imaging – Include IR scanning in routine maintenance to detect hidden heating.
  5. Load Monitoring – Use meters to monitor load trends and balance phases.
  6. Ventilation Check – Ensure sufficient airflow in switchgear rooms.
  7. Test Relays and Trip Units – Ensure settings are correct and functioning properly.
  8. Record Keeping – Maintain a logbook of inspections, defects, and corrective actions.

Case Studies of ACB Heating Issues

Case Study 1: Loose Busbar Connection

  • Problem: A 3200A ACB installed in a commercial building showed heating on phase R.
  • Diagnosis: Infrared scan showed 120°C at one terminal.
  • Solution: Tightened the busbar connection and applied conductive paste.
  • Result: Temperature dropped to 45°C.

Case Study 2: Overloaded ACB

  • Problem: A 2500A ACB in a manufacturing plant was heating continuously.
  • Diagnosis: Load current measured 2800A due to expansion of production lines.
  • Solution: Replaced with a 3200A breaker.
  • Result: No more heating issues.

Case Study 3: Harmonic Heating

  • Problem: A 1600A ACB in a data center tripped frequently.
  • Diagnosis: THD of current was 25% due to large UPS loads.
  • Solution: Installed passive harmonic filters.
  • Result: Current waveform improved, heating reduced.

Difference Between Normal Heating and Abnormal Heating

ParameterNormal Heating in ACBAbnormal Heating in ACB
Temperature riseWithin manufacturer’s limit (40–50°C)Exceeds 70°C, terminals hot to touch
CauseNormal I²R lossLoose connections, overload, harmonics
ImpactNo effect on lifeReduces lifespan, risk of failure
Action requiredRoutine checkImmediate corrective action needed

Expert Tips to Avoid Heating Issues

  • Always size ACB based on future load growth, not just present needs.
  • Use silver-plated contacts for high-current applications.
  • Periodically check spring pressure of contacts.
  • Provide separate neutral busbar for nonlinear loads.
  • Schedule shutdown maintenance to carry out detailed inspection.
  • Train operators to recognize early warning signs like smell of burning insulation or humming noise.

Future Trends: Smart ACBs for Monitoring Heating Issues

Modern ACBs come with smart trip units and IoT-enabled monitoring features. These breakers can measure:

  • Real-time current
  • Power quality parameters
  • Contact wear
  • Thermal stress indicators

With predictive maintenance, smart ACBs can alert operators before heating issues escalate into failures. This reduces downtime and ensures higher reliability.

So, why ACB getting heating issue? The answer lies in multiple factors—loose connections, overload, phase imbalance, harmonics, contact wear, poor ventilation, and lack of maintenance.

The key takeaway is:
👉 Heating is always a warning sign. Ignoring it can cause costly downtime or dangerous failures.

By conducting regular inspections, load analysis, contact resistance tests, and ensuring proper environmental conditions, ACB heating problems can be minimized.

In the modern era, industries should also consider smart ACBs with monitoring features for predictive maintenance.

Remember: Prevention is always better than breakdown. A properly maintained ACB not only prevents heating issues but also ensures the safety and efficiency of your entire power distribution system.